Eaves - Composite Panels

3D Interactive PDF Version Available
Click Diagram To View!
(Requires Free Acrobat Reader 7.0.07 or better)

Click To View 3d Interactive Model

    Key Features
  • Roof supported gutter avoids thermal bridge issues.
  • Eaves flashings, insulation and filler must be installed carefully to achieve a low Y value.
  • Liner must not cut across insulation.
  • All fixings and seals must be to manufacturers' recommendations.
  • Seal holes and joints in eaves beam to avoid by-passing liner seals.