Overhanging Eaves - Twin Skin (No Liner Bridge)

3D Interactive PDF Version Available
Click Diagram To View!
(Requires Free Acrobat Reader 7.0.07 or better)

Click To View 3d Interactive Model

    Key Features
  • Detail depends on being able to air seal effectively at stub steelwork and eaves beam. i.e. part of the steel design.
  • There will be thermal bridging through stub, but an alternative would involve insulating soffit, fascia and gutter, and the gutter will probably still be a thermal bridge.